Delphi
Discontinued

Delphi FG2298 Fuel Pump Module Assembly

Brand Delphi FG2298
Outlet Outside Diameter 0.375
Voltage 12.0
Fuel Type Gas
Regulator Included Yes
Maximum Pressure 79.0
Terminal Type Blade
Gasket Or Seal Included No
Terminal Quantity 4
Lock Ring Included No
Terminal Gender Male
Strainer Included Yes
Inlet Type Strainer
Outlet Type Quick connect
Outlet Quantity 2
In Tank or External In tank
Resistance Ohms Empty 180.0
Resistance Ohms Full 10.0
Internal Or External Strainer Internal
Average Current Draw 9
Average Flow Rating 24
Pump Type Electric
Fuel Level Sender Assembly Included Yes
Item Grade Standard replacement
Package Contents Fuel pump module assembly w/float arm, instruction sheet
System Pressure 58 psi
Vapor Pressure Sensor No
Product line Discontinued
Fits Ford and Lincoln · 18 vehicles

OE heritage. Built from Delphi's long OE supply experience for fuel system service.

Integrated regulator. Includes a fuel pressure regulator and sender assembly in one module.

Standard replacement. Designed as a service-ready fuel pump module for gasoline systems.

Cross-references DFG2298, DG9Z 9H307-AC and DG9Z9H307K for the same application. See all 7.

$209.16Free shipping
In stock · usually ships same day before 1pm CST
Step 1 — Confirm fitment
Free return shipping if it doesn't fit when you check fitment here first.
Select your vehicle to confirm fitment
Verify this part fits before purchasing — free returns if it doesn't
Step 2 — Quantity
Order total $209.16
Free shipping to the continental U.S.
Free returns within 60 days if it doesn't fit when fitment is verified.

Fuel Pump Module Overview

This Delphi fuel pump module assembly is a standard replacement for gasoline applications that require an in-tank electric pump with an integrated regulator and fuel level sender. It is built for select Ford Fusion and Lincoln MKZ applications and uses a quick-connect outlet for service-friendly installation.

Key Features

  • In-tank electric fuel pump module for gasoline systems
  • Integrated fuel pressure regulator and fuel level sender assembly
  • Quick-connect outlet with blade-style, 4-terminal electrical connection
  • Internal strainer included for fuel pickup protection
  • Standard replacement design for select Ford and Lincoln applications

Detailed Description

Delphi FG2298 is a fuel pump module assembly engineered for vehicles that use a 12-volt in-tank electric pump with a regulated fuel delivery system. It is specified with a maximum pressure rating of 79 psi, a system pressure of 58 psi, and an average flow rating of 24, making it a direct service part for fuel delivery restoration. The module includes a float arm and fuel level sender assembly, and it uses a quick-connect outlet with two outlets for the fuel line connection. Delphi FG2298 reflects the brand’s OE experience and long-standing supply background, which is carried into its aftermarket fuel system coverage.

This part cross-references Monroe Shocks & Struts (e.g., DFG2298, DG9Z 9H307-AC) for the same application.

What It Helps Address

  • Hard starting caused by weak fuel delivery
  • Engine stalling from inconsistent fuel pressure
  • Fuel gauge readings affected by sender wear
  • Poor drivability linked to a failing in-tank pump module
  • Fuel system service needs on select Ford Fusion and Lincoln MKZ models

Installation Notes

Compatible With 2016-2020 Ford Fusion, N/A, and 2017-2020 Lincoln MKZ, N/A. The 2016 Ford Fusion application is limited to vehicles built from 09/24/2015 and excludes Clean Fuel Fleet Vehicle models. Clean the fuel tank before installation to reduce the risk of contaminating the replacement pump. A fuel tank cleaning kit is recommended by the manufacturer for this service.

Quality Assurance

Delphi draws on 100 years of OE experience and supplier knowledge used by major automakers. FG2298 is a standard replacement fuel pump module assembly built around OE-oriented fuel system requirements.

This part fits 18 vehicles
Always verify fitment with your vehicle's VIN if unsure. Submodel & trim restrictions may apply.
YearMakeModelDrive TypeFuel TypeNotes
2020FordFusion—GASExcept Clean Fuel Fleet Vehicle; Fuel tank contamination is the leading cause of premature fuel pump failure. To reduce risk of contaminating the replacement pump, it’s recommended to clean the fuel tank before installing a new pump.; Use of fuel tank cleaning kit FC01 is recommended.; Discontinued
2020FordFusionFWDGASExcept Clean Fuel Fleet Vehicle; Fuel tank contamination is the leading cause of premature fuel pump failure. To reduce risk of contaminating the replacement pump, it’s recommended to clean the fuel tank before installing a new pump.; Use of fuel tank cleaning kit FC01 is recommended.; Discontinued
2020FordFusion——Except Clean Fuel Fleet Vehicle; Fuel tank contamination is the leading cause of premature fuel pump failure. To reduce risk of contaminating the replacement pump, it’s recommended to clean the fuel tank before installing a new pump.; Use of fuel tank cleaning kit FC01 is recommended.; Discontinued
2020LincolnMKZFWDGASExcept Clean Fuel Fleet Vehicle; Fuel tank contamination is the leading cause of premature fuel pump failure. To reduce risk of contaminating the replacement pump, it’s recommended to clean the fuel tank before installing a new pump.; Use of fuel tank cleaning kit FC01 is recommended.; Discontinued
2019FordFusion—GASExcept Clean Fuel Fleet Vehicle; Fuel tank contamination is the leading cause of premature fuel pump failure. To reduce risk of contaminating the replacement pump, it’s recommended to clean the fuel tank before installing a new pump.; Use of fuel tank cleaning kit FC01 is recommended.; Discontinued
2019FordFusionFWDGASExcept Clean Fuel Fleet Vehicle; Fuel tank contamination is the leading cause of premature fuel pump failure. To reduce risk of contaminating the replacement pump, it’s recommended to clean the fuel tank before installing a new pump.; Use of fuel tank cleaning kit FC01 is recommended.; Discontinued
2019FordFusion——Except Clean Fuel Fleet Vehicle; Fuel tank contamination is the leading cause of premature fuel pump failure. To reduce risk of contaminating the replacement pump, it’s recommended to clean the fuel tank before installing a new pump.; Use of fuel tank cleaning kit FC01 is recommended.; Discontinued
2019LincolnMKZFWDGASExcept Clean Fuel Fleet Vehicle; Fuel tank contamination is the leading cause of premature fuel pump failure. To reduce risk of contaminating the replacement pump, it’s recommended to clean the fuel tank before installing a new pump.; Use of fuel tank cleaning kit FC01 is recommended.; Discontinued
2018FordFusion—GASExcept Clean Fuel Fleet Vehicle; Fuel tank contamination is the leading cause of premature fuel pump failure. To reduce risk of contaminating the replacement pump, it’s recommended to clean the fuel tank before installing a new pump.; Use of fuel tank cleaning kit FC01 is recommended.; Discontinued
2018FordFusionFWDGASExcept Clean Fuel Fleet Vehicle; Fuel tank contamination is the leading cause of premature fuel pump failure. To reduce risk of contaminating the replacement pump, it’s recommended to clean the fuel tank before installing a new pump.; Use of fuel tank cleaning kit FC01 is recommended.; Discontinued
2018FordFusion——Except Clean Fuel Fleet Vehicle; Fuel tank contamination is the leading cause of premature fuel pump failure. To reduce risk of contaminating the replacement pump, it’s recommended to clean the fuel tank before installing a new pump.; Use of fuel tank cleaning kit FC01 is recommended.; Discontinued
2018LincolnMKZFWDGASExcept Clean Fuel Fleet Vehicle; Fuel tank contamination is the leading cause of premature fuel pump failure. To reduce risk of contaminating the replacement pump, it’s recommended to clean the fuel tank before installing a new pump.; Use of fuel tank cleaning kit FC01 is recommended.; Discontinued
2017FordFusion—GASExcept Clean Fuel Fleet Vehicle; Fuel tank contamination is the leading cause of premature fuel pump failure. To reduce risk of contaminating the replacement pump, it’s recommended to clean the fuel tank before installing a new pump.; Use of fuel tank cleaning kit FC01 is recommended.; Discontinued
2017FordFusionFWDGASExcept Clean Fuel Fleet Vehicle; Fuel tank contamination is the leading cause of premature fuel pump failure. To reduce risk of contaminating the replacement pump, it’s recommended to clean the fuel tank before installing a new pump.; Use of fuel tank cleaning kit FC01 is recommended.; Discontinued
2017FordFusion——Except Clean Fuel Fleet Vehicle; Fuel tank contamination is the leading cause of premature fuel pump failure. To reduce risk of contaminating the replacement pump, it’s recommended to clean the fuel tank before installing a new pump.; Use of fuel tank cleaning kit FC01 is recommended.; Discontinued
2017LincolnMKZFWDGASExcept Clean Fuel Fleet Vehicle; Fuel tank contamination is the leading cause of premature fuel pump failure. To reduce risk of contaminating the replacement pump, it’s recommended to clean the fuel tank before installing a new pump.; Use of fuel tank cleaning kit FC01 is recommended.; Discontinued
2016FordFusionFWDGASExcept Clean Fuel Fleet Vehicle; From 09/24/2015; Fuel tank contamination is the leading cause of premature fuel pump failure. To reduce risk of contaminating the replacement pump, it’s recommended to clean the fuel tank before installing a new pump.; Use of fuel tank cleaning kit FC01 is recommended.; Discontinued
2016FordFusion——Except Clean Fuel Fleet Vehicle; Fuel tank contamination is the leading cause of premature fuel pump failure. To reduce risk of contaminating the replacement pump, it’s recommended to clean the fuel tank before installing a new pump.; Use of fuel tank cleaning kit FC01 is recommended.; Discontinued
Directly replaces or cross-references 7 part numbers
Cross-reference numbers are provided for identification purposes only. Always confirm fitment before ordering.
DFG2298DG9Z 9H307-ACDG9Z9H307KDG9Z9H307XFP5Z 9H307-DPFS1044PFS1131