/live/media/NO/NO_24595_Fro.jpg)
Will it fit your vehicle?
Confirm before you buy. Free return shipping if it doesn't fit.
NTK 24595 Oxygen Sensor - Downstream or Upstream
| Brand | NTK 24595 |
|---|---|
| Position | Downstream and Upstream |
| Wiring Harness Length | 9.0000 |
| Sensor Type | Heated |
| Universal Or Specific Fit | Specific |
| Wire Quantity | 4 |
| Thread Diameter | 18.000 |
| Mounting Type | Flange |
| Product line | Direct Fit Oxygen Sensor |
| Fits | Toyota · 17 vehicles |
Direct fit design. Built for specific applications with OE-style fit, form, and function.
Heated sensor. 4-wire construction with a 9-inch harness for clean signal and heater routing.
OE manufacturing background. NTK applies extensive testing to support quality and reliability.
Cross-references Bosch 13104, Delphi ES20119 and DENSO Auto Parts 234-4154 for the same application. See all 12.
Will it fit your vehicle?
Free return shipping if it doesn't fit.
Direct Fit Oxygen Sensor for Toyota Applications
NTK 24595 is a direct fit oxygen sensor built for specific Toyota applications, including 1993-2000 Toyota 4Runner, 1993-1995 Toyota Pickup, and 1996-1998 Toyota T100. It uses a heated, 4-wire design with a 9-inch harness and an 18 mm thread diameter for OE-style replacement fitment.
Key Features
- Direct fit design for specific applications
- Heated oxygen sensor construction
- 4-wire configuration for signal and heater circuits
- 9-inch wiring harness length
- 18 mm thread diameter with flange mounting type
- NTK 24595 for emission control service
Detailed Description
NTK 24595 is part of the Direct Fit Oxygen Sensor line, engineered for specific import and domestic applications with OE-style fit, form, and function. This sensor is used in Toyota 4Runner, Toyota Pickup, and Toyota T100 fitments listed for upstream and downstream positions, with notes covering California emissions and production-specific applications. The part number 24595 is supported by NTK's OE sensor manufacturing background and manufacturing controls focused on quality and reliability.
NTK is recognized as a major original equipment oxygen sensor supplier, and this product reflects that focus through application-specific coverage and tested manufacturing standards. For buyers replacing a worn oxygen sensor on a Toyota 4Runner, Toyota Pickup, or Toyota T100, NTK 24595 provides a direct fit solution matched to the listed vehicle configurations.
What It Is Used For
- Replacing a failed oxygen sensor that can trigger check engine lights
- Restoring air-fuel ratio feedback for engine management
- Addressing poor fuel control caused by inaccurate exhaust readings
- Correcting emissions-related faults on listed Toyota applications
- Servicing upstream or downstream sensor locations shown in fitment
Installation Notes and Tips
Verify the listed year, make, model, position, and emissions notes before installation. This NTK 24595 sensor uses a flange mounting type, a heated 4-wire layout, and an 18 mm thread diameter, so confirm connector routing and harness length against the original part before replacement.
Quality Assurance
NTK tests oxygen sensors during manufacturing to help ensure quality and reliability that meet or exceed OE specifications. The brand's OE manufacturing background and application-specific design support consistent replacement performance for the listed Toyota fitments.
| Year | Make | Model | Drive Type | Transmission | Liters | Cylinders | Position | Notes |
|---|---|---|---|---|---|---|---|---|
| 2000 | Toyota | 4Runner | 4WD | Automatic | 2.7L | L4 | Downstream | Downstream oxygen sensor with original equipment equivalent design; Direct Fit Oxygen Sensor |
| 1999 | Toyota | 4Runner | 4WD | Automatic | 2.7L | L4 | Downstream | Downstream oxygen sensor with original equipment equivalent design; Direct Fit Oxygen Sensor |
| 1998 | Toyota | 4Runner | 4WD | Automatic | 2.7L | L4 | Downstream | Downstream oxygen sensor with original equipment equivalent design; Direct Fit Oxygen Sensor |
| 1998 | Toyota | T100 | — | Manual | 2.7L | L4 | Upstream | OE design oxygen sensor fits Bank 1 Sensor 1 for air/fuel ratio.; Direct Fit Oxygen Sensor |
| 1997 | Toyota | 4Runner | 4WD | Automatic | 2.7L | L4 | Downstream | Downstream oxygen sensor with original equipment equivalent design; Direct Fit Oxygen Sensor |
| 1997 | Toyota | T100 | — | Manual | 2.7L | L4 | Upstream | OE design oxygen sensor fits Bank 1 Sensor 1 for air/fuel ratio.; Direct Fit Oxygen Sensor |
| 1996 | Toyota | 4Runner | 4WD | Automatic | 2.7L | L4 | Downstream | Downstream oxygen sensor with original equipment equivalent design; Direct Fit Oxygen Sensor |
| 1996 | Toyota | T100 | — | Manual | 2.7L | L4 | Upstream | OE design oxygen sensor fits Bank 1 Sensor 1 for air/fuel ratio.; Direct Fit Oxygen Sensor |
| 1995 | Toyota | 4Runner | — | — | 2.4L | L4 | Downstream | B1S2 California emissions OE equivalent design.; Direct Fit Oxygen Sensor |
| 1995 | Toyota | Pickup | — | — | 2.4L | L4 | Downstream | B1S2; Calif. Emissions; Japan Production; OE Equivalent Design; Direct Fit Oxygen Sensor |
| 1995 | Toyota | Pickup | 4WD | — | 2.4L | L4 | Downstream | B1S2; Calif. Emissions; North American Production; Long Bed; OE Equivalent Design; Direct Fit Oxygen Sensor |
| 1994 | Toyota | 4Runner | — | — | 2.4L | L4 | Downstream | B1S2 California emissions OE equivalent design.; Direct Fit Oxygen Sensor |
| 1994 | Toyota | Pickup | — | — | 2.4L | L4 | Downstream | B1S2; Calif. Emissions; Japan Production; OE Equivalent Design; Direct Fit Oxygen Sensor |
| 1994 | Toyota | Pickup | 4WD | — | 2.4L | L4 | Downstream | B1S2; Calif. Emissions; North American Production; Long Bed; OE Equivalent Design; Direct Fit Oxygen Sensor |
| 1993 | Toyota | 4Runner | — | — | 2.4L | L4 | Downstream | B1S2 California emissions OE equivalent design.; Direct Fit Oxygen Sensor |
| 1993 | Toyota | Pickup | — | — | 2.4L | L4 | Downstream | B1S2; Calif. Emissions; Japan Production; OE Equivalent Design; Direct Fit Oxygen Sensor |
| 1993 | Toyota | Pickup | 4WD | — | 2.4L | L4 | Downstream | B1S2; Calif. Emissions; North American Production; Long Bed; OE Equivalent Design; Direct Fit Oxygen Sensor |
| No rows match your filter. | ||||||||