HomeEmission Control > SensorsWalker 250-23032 Oxygen Sensor - Upstream, Upstream Left or Upstream Right
Part #: 250-23032

Walker 250-23032 Oxygen Sensor - Upstream, Upstream Left or Upstream Right

Walker Products OE, Upstream Left
⚙️ 12 vehicles fit this part
🔍
Select your vehicle to confirm fitment
Verify this part fits before purchasing — free returns if it doesn't
$70.35Free Shipping
🚚Free ShippingNo Cost to Continental U.S.
🔄Free Returns*Wrong fit? No cost
🛡️60-Day ReturnsMoney back guarantee
*Free return shipping only qualifies if our fitment verification tool is used.
🔥
✅ In Stock · Ready To Ship Most orders ship same-day if ordered before 1pm CST.
OE Direct Replacement — Bolt-on fit, no modifications needed
📦Walker Products OE, Upstream Left
🚗Fitment: Audi and Peugeot, 100 Quattro, 90 Quattro, 100, and 505
🔄Easy Returns — Return within 60 days for a full refund
🚚Fast Shipping — Most orders ship same business day before 1pm CST

Overview of Walker 250-23032 Oxygen Sensor for Audi Vehicles

The Walker 250-23032 oxygen sensor is designed specifically for select Audi models, including the 90 Quattro, 100, and 100 Quattro. This heated oxygen sensor ensures accurate emissions control and optimal engine performance by monitoring exhaust gases effectively.

  • Heated oxygen sensor with 3-wire configuration
  • Specific fit for Audi 90 Quattro, 100, and 100 Quattro models
  • Threaded mounting type with 18.0 mm thread diameter
  • Wiring harness length of 17.44 inches and overall length of 20.98 inches
  • Radiused polygon connector shape with male and female connectors
  • Wire gauge measurement of 20 for reliable electrical performance

Detailed Product Features and Specifications

This Walker oxygen sensor (part number 250-23032) features a heated sensor type that allows for quicker activation and more accurate readings under various operating conditions. The sensor includes a 3-wire design, which supports both the heating element and signal transmission. Its wiring harness length of 17.44 inches and overall length of 20.98 inches provide sufficient reach for proper installation in the exhaust system. The sensor mounts via a threaded connection with an 18.0 mm diameter, ensuring a secure fit. The radiused polygon connector shape with both male and female connectors facilitates a precise and reliable electrical connection.

Walker Products OE Brand Line Information

The Walker Products OE line focuses on delivering original equipment quality parts that meet or exceed OEM specifications. This oxygen sensor is part of the Walker Products OE series, which emphasizes durability and precise fitment for specific vehicle applications. Using a Walker Products OE sensor helps maintain factory-level emissions control and engine efficiency for your Audi 90 Quattro, 100, or 100 Quattro.

Common Applications and Issues Addressed

  • Replacement for faulty or failing oxygen sensors in Audi 90 Quattro, 100, and 100 Quattro
  • Helps resolve rough idling and poor fuel economy caused by inaccurate oxygen readings
  • Reduces emissions by ensuring proper air-fuel mixture monitoring
  • Prevents check engine light triggers related to oxygen sensor faults
  • Supports optimal engine performance and reduced exhaust emissions

Installation Notes and Tips

When installing the Walker 250-23032 oxygen sensor, ensure the threaded mounting hole is clean and free of debris. Use appropriate anti-seize compound on the threads if recommended by the vehicle manufacturer. Verify the wiring harness length and connector types match the vehicle’s original sensor to avoid electrical issues. Proper torque specifications should be followed to prevent damage to the sensor or exhaust components.

Quality Assurance and Warranty

Walker Products OE oxygen sensors are manufactured to meet strict quality standards and undergo rigorous testing to ensure reliable performance. While specific warranty details may vary, Walker typically offers coverage against defects in materials and workmanship. Using this sensor helps maintain compliance with emissions regulations and supports long-term vehicle operation.

BrandWalker
Part Number250-23032
PositionWalker Products OE, Upstream Left
Connector GenderFemale
Connector GenderMale
Connector ShapeRadiused Polygon
Mounting TypeThreaded
Overall Length20.98
Sensor TypeHeated
Thread Diameter18.0
Universal Or Specific FitSpecific
Wire Gauge Measurement20
Wire Quantity3
Wiring Harness Length17.44

This part fits 12 vehicles. Search below:

YearMakeModelLitersCylindersFuel TypePositionNotes
1993Audi100 Quattro2.8LV6GASUpstream RightTo Chassis # 4A-P-022 306; Para Chasis 4A-P-022 306; Upstream; Right; Walker Products OE
1993Audi100 Quattro2.8LV6GASUpstream LeftTo Chassis # 4A-P-022 306; Para Chasis 4A-P-022 306; Upstream; Left; Walker Products OE
1993Audi100 Quattro2.8LV6GASUpstream RightUpstream oxygen sensor on the right side for Chassis # 4A-P-022 306; Walker Products OE
1993Audi100 Quattro2.8LV6GASUpstream LeftTo Chassis # 4A-P-022 306; Upstream; Left; Walker Products OE
1993Audi90 Quattro2.8LV6GASUpstream RightTo Chassis # 8C-P-190 000; Para Chasis 8C-P-190 000; Upstream; Right; Walker Products OE
1993Audi90 Quattro2.8LV6GASUpstream LeftTo Chassis # 8C-P-190 000; Para Chasis 8C-P-190 000; Upstream; Left; Walker Products OE
1993Audi90 Quattro2.8LV6GASUpstream RightChassis # 8C-P-190 000; Upstream; Right; Walker Products OE
1993Audi90 Quattro2.8LV6GASUpstream LeftTo Chassis # 8C-P-190 000; Upstream; Left; Walker Products OE
1992Audi1002.8LV6GASUpstream RightInstall upstream oxygen sensor on the right side.; Walker Products OE
1992Audi1002.8LV6GASUpstream LeftInstall upstream oxygen sensor on the left side.; Walker Products OE
1992Audi100 Quattro2.8LV6GASUpstream RightInstall upstream oxygen sensor on the right side.; Walker Products OE
1992Audi100 Quattro2.8LV6GASUpstream LeftInstall upstream oxygen sensor on the left side.; Walker Products OE

* Always verify fitment with your vehicle's VIN if unsure. Submodel & trim restrictions may apply.

This part directly replaces or is cross-referenced with the following part numbers:

Cross-reference numbers are provided for identification purposes only. Always confirm fitment before ordering.