HomeEmission Control > SensorsWalker 250-23060 Oxygen Sensor - Upstream
Part #: 250-23060

Walker 250-23060 Oxygen Sensor - Upstream

Walker Products OE, Upstream
32 vehicles fit this part
Select your vehicle to confirm fitment
Verify this part fits before purchasing — free returns if it doesn't
$81.83Free Shipping
Free ShippingNo Cost to Continental U.S.
Free Returns*Wrong fit? No cost
60-Day ReturnsMoney back guarantee
*Free return shipping only qualifies if our fitment verification tool is used.
In Stock · Ready To Ship Most orders ship same-day if ordered before 1pm CST.
OE Direct Replacement — Bolt-on fit, no modifications needed
Walker Products OE, Upstream
Fitment: Porsche, 928, 911, and 944
Easy Returns — Return within 60 days for a full refund
Fast Shipping — Most orders ship same business day before 1pm CST

Overview of Walker 250-23060 Oxygen Sensor for Porsche Models

The Walker 250-23060 oxygen sensor is designed specifically for Porsche 911, 928, and 944 models. This heated oxygen sensor ensures accurate emissions control and optimal engine performance by providing precise air-fuel mixture data to the vehicle's engine management system.

  • Heated sensor type for faster response times
  • Specific fit for Porsche 911, 928, and 944 models
  • Threaded mounting type with 18.0 mm thread diameter
  • 25.12-inch wiring harness length with 3 wires of 20 gauge
  • Radiused polygon male connector for secure connection
  • Overall length of 28.66 inches for proper installation

Detailed Features and Specifications

This oxygen sensor from Walker Products OE features a heated sensor element that allows quicker warm-up and more accurate readings under various operating conditions. The 3-wire design with 20 gauge wiring ensures reliable signal transmission and durability. The sensor is threaded with an 18.0 mm diameter, making it compatible with the original mounting points on Porsche 911, 928, and 944 vehicles. The radiused polygon male connector provides a secure and precise fit, reducing the risk of connection issues. With a wiring harness length of 25.12 inches and an overall length of 28.66 inches, this sensor is engineered for proper fitment and ease of installation.

Walker Products OE Brand Line Information

The Walker Products OE line focuses on delivering emission control components that meet or exceed original equipment specifications. This oxygen sensor is part of that line, ensuring compatibility and performance consistent with factory standards for Porsche vehicles. The OE designation indicates that the part is designed to match the fit, form, and function of the original sensor installed on the vehicle.

Common Applications and Problem Resolution

  • Restores accurate oxygen sensing for proper air-fuel mixture control
  • Helps resolve check engine light issues related to oxygen sensor faults
  • Improves fuel efficiency by providing precise emissions data
  • Reduces harmful exhaust emissions by maintaining proper combustion
  • Prevents engine performance problems caused by faulty sensor readings

Installation Notes and Tips

When installing the Walker 250-23060 oxygen sensor, ensure the vehicle is cool to avoid burns. Use the correct tools to remove the old sensor and avoid damaging the threaded mounting hole. Verify the connector type matches the vehicle harness before installation. The 25.12-inch wiring harness length provides flexibility during installation, but routing should avoid heat sources and moving parts. Tighten the sensor to the manufacturer’s torque specifications to ensure a proper seal.

Quality Assurance and Warranty

Walker Products OE oxygen sensors are manufactured to meet strict quality standards for durability and performance. This part undergoes rigorous testing to ensure reliable operation in Porsche 911, 928, and 944 models. While specific warranty details are not provided here, Walker typically offers coverage against defects in materials and workmanship, supporting long-term vehicle emissions compliance.

BrandWalker
Part Number250-23060
PositionWalker Products OE, Upstream
Connector GenderMale
Connector ShapeRadiused Polygon
Mounting TypeThreaded
Overall Length28.66
Sensor TypeHeated
Thread Diameter18.0
Universal Or Specific FitSpecific
Wire Gauge Measurement20
Wire Quantity3
Wiring Harness Length25.12

This part fits 32 vehicles. Search below:

YearMakeModelLitersCylindersFuel TypePositionNotes
1995Porsche9285.4LV8GASUpstreamInstall upstream oxygen sensor for optimal performance.; Walker Products OE
1994Porsche9113.6LH6GASUpstream3-wire Oxygen Sensor; Upstream; Walker Products OE
1994Porsche9113.6LH6GASUpstream3-wire upstream oxygen sensor; Walker Products OE
1994Porsche9285.4LV8GASUpstreamInstall upstream oxygen sensor for optimal performance.; Walker Products OE
1993Porsche9113.6LH6GASUpstreamInstall upstream oxygen sensor for optimal performance.; Walker Products OE
1993Porsche9285.4LV8GASUpstreamInstall upstream oxygen sensor for optimal performance.; Walker Products OE
1992Porsche9113.6LH6GASUpstreamInstall upstream oxygen sensor for optimal performance.; Walker Products OE
1992Porsche9113.3LH6GASUpstreamInstall upstream oxygen sensor for optimal performance.; Walker Products OE
1991Porsche9113.6LH6GASUpstreamInstall upstream oxygen sensor for optimal performance.; Walker Products OE
1991Porsche9113.3LH6GASUpstreamInstall upstream oxygen sensor for optimal performance.; Walker Products OE
1991Porsche9285.0LV8GASUpstreamInstall upstream oxygen sensor for optimal performance.; Walker Products OE
1990Porsche9113.6LH6GASUpstreamInstall upstream oxygen sensor for optimal performance.; Walker Products OE
1990Porsche9285.0LV8GASUpstreamInstall upstream oxygen sensor for optimal performance.; Walker Products OE
1989Porsche9113.6LH6GASUpstreamInstall upstream oxygen sensor for optimal performance.; Walker Products OE
1989Porsche9113.3LH6GASUpstreamInstall upstream oxygen sensor for optimal performance.; Walker Products OE
1989Porsche9113.2LH6GASUpstreamInstall upstream oxygen sensor for optimal performance.; Walker Products OE
1989Porsche9285.0LV8GASUpstreamInstall upstream oxygen sensor for optimal performance.; Walker Products OE
1989Porsche9442.5LL4GASUpstreamBank 1 Sensor 1 needs an upstream oxygen sensor.; Walker Products OE
1989Porsche9442.5LL4GASUpstreamFront oxygen sensor compatible with various vehicle models.; Walker Products OE
1988Porsche9113.3LH6GASUpstreamInstall upstream oxygen sensor for optimal performance.; Walker Products OE
1988Porsche9113.2LH6GASUpstreamInstall upstream oxygen sensor for optimal performance.; Walker Products OE
1988Porsche9285.0LV8GASUpstreamInstall upstream oxygen sensor for optimal performance.; Walker Products OE
1988Porsche9442.5LL4GASUpstreamBank 1 Sensor 1 needs an upstream oxygen sensor.; Walker Products OE
1988Porsche9442.5LL4GASUpstreamFront oxygen sensor compatible with various vehicle models.; Walker Products OE
1987Porsche9113.3LH6GASUpstreamInstall upstream oxygen sensor for optimal performance.; Walker Products OE
1987Porsche9113.2LH6GASUpstreamInstall upstream oxygen sensor for optimal performance.; Walker Products OE
1987Porsche9442.5LL4GASUpstreamBank 1 Sensor 1 needs an upstream oxygen sensor.; Walker Products OE
1987Porsche9442.5LL4GASUpstreamFront oxygen sensor compatible with various vehicle models.; Walker Products OE
1986Porsche9113.3LH6GASUpstreamInstall upstream oxygen sensor for optimal performance.; Walker Products OE
1986Porsche9113.2LH6GASUpstreamInstall upstream oxygen sensor for optimal performance.; Walker Products OE
1986Porsche9442.5LL4GASUpstreamBank 1 Sensor 1 needs an upstream oxygen sensor.; Walker Products OE
1986Porsche9442.5LL4GASUpstreamFront oxygen sensor compatible with various vehicle models.; Walker Products OE

* Always verify fitment with your vehicle's VIN if unsure. Submodel & trim restrictions may apply.

This part directly replaces or is cross-referenced with the following part numbers:

Cross-reference numbers are provided for identification purposes only. Always confirm fitment before ordering.