OE Quality
60-Day Returns

Walker 250-24314 Oxygen Sensor - Upstream
Overview of Walker 250-24314 Oxygen Sensor for Chrysler and Dodge
The Walker 250-24314 oxygen sensor is designed specifically for Chrysler Caravan and Dodge Voyager models. This heated oxygen sensor ensures accurate emissions control and optimal engine performance by monitoring exhaust gases effectively.
- Heated oxygen sensor with 4 wires for precise readings
- Specific fit for Chrysler Caravan and Dodge Voyager vehicles
- 9.57-inch wiring harness length for convenient installation
- Threaded mounting type with 18.0 mm thread diameter
- Radiused polygon female connector for secure connection
- Overall length of 13.11 inches for proper fitment
- 20 gauge wire measurement for durability and signal integrity
Detailed Features and Specifications
This Walker Products OE oxygen sensor (part number 250-24314) features a heated sensor type that allows for faster warm-up times and improved fuel efficiency. The sensor includes a 9.57-inch wiring harness and four wires, which provide reliable signal transmission. Its radiused polygon female connector ensures a secure and precise connection to the vehicle’s wiring system. The threaded mounting type with an 18.0 mm diameter allows for straightforward installation in the exhaust system. With an overall length of 13.11 inches, this sensor fits perfectly in the designated location on Chrysler Caravan and Dodge Voyager models.
Walker Products OE Brand Line Information
The Walker Products OE line focuses on delivering original equipment quality parts that meet or exceed OEM specifications. This oxygen sensor is part of that line, ensuring compatibility and performance consistent with factory-installed components. Choosing a Walker Products OE sensor helps maintain the integrity of your vehicle’s emission control system.
Common Applications and Problem Resolution
- Restores accurate oxygen level readings for proper air-fuel mixture
- Helps resolve rough idling and engine hesitation issues
- Reduces emissions by ensuring efficient catalytic converter operation
- Prevents check engine light triggers related to oxygen sensor faults
- Improves fuel economy by maintaining optimal combustion
Installation Notes and Tips
When installing the Walker 250-24314 oxygen sensor, ensure the vehicle is cool to avoid burns. Use the correct tools to remove the old sensor and avoid damaging the wiring harness. Verify the connector type matches the vehicle’s harness before installation. Thread the sensor carefully to prevent cross-threading and tighten to manufacturer torque specifications. Proper installation will ensure accurate sensor readings and long-term reliability.
Quality Assurance and Warranty
Walker Products OE oxygen sensors are manufactured to meet strict quality standards and undergo rigorous testing to ensure durability and performance. This part is backed by Walker’s quality assurance, providing confidence in its fitment and function for Chrysler Caravan and Dodge Voyager vehicles. Please refer to Walker’s warranty policy for specific coverage details.
| Brand | Walker |
|---|---|
| Part Number | 250-24314 |
| Position | Walker Products OE, Upstream |
| Connector Gender | Female |
| Connector Shape | Radiused Polygon |
| Mounting Type | Threaded |
| Overall Length | 13.11 |
| Sensor Type | Heated |
| Thread Diameter | 18.0 |
| Universal Or Specific Fit | Specific |
| Wire Gauge Measurement | 20 |
| Wire Quantity | 4 |
| Wiring Harness Length | 9.57 |
This part fits 12 vehicles. Search below:
| Year | Make | Model | Liters | Cylinders | Fuel Type | Position | Notes |
|---|---|---|---|---|---|---|---|
| 2003 | Chrysler | Voyager | 2.4L | L4 | GAS | Upstream | Bank 1 Sensor 1 needs an upstream oxygen sensor.; Walker Products OE |
| 2003 | Chrysler | Voyager | 2.4L | L4 | GAS | Upstream | Front oxygen sensor compatible with various vehicle models.; Walker Products OE |
| 2003 | Dodge | Caravan | 2.4L | L4 | GAS | Upstream | Bank 1 Sensor 1 needs an upstream oxygen sensor.; Walker Products OE |
| 2003 | Dodge | Caravan | 2.4L | L4 | GAS | Upstream | Front oxygen sensor compatible with various vehicle models.; Walker Products OE |
| 2002 | Chrysler | Voyager | 2.4L | L4 | GAS | Upstream | Bank 1 Sensor 1 needs an upstream oxygen sensor.; Walker Products OE |
| 2002 | Chrysler | Voyager | 2.4L | L4 | GAS | Upstream | Front oxygen sensor compatible with various vehicle models.; Walker Products OE |
| 2002 | Dodge | Caravan | 2.4L | L4 | GAS | Upstream | Bank 1 Sensor 1 needs an upstream oxygen sensor.; Walker Products OE |
| 2002 | Dodge | Caravan | 2.4L | L4 | GAS | Upstream | Front oxygen sensor compatible with various vehicle models.; Walker Products OE |
| 2001 | Chrysler | Voyager | 2.4L | L4 | GAS | Upstream | Bank 1 Sensor 1 needs an upstream oxygen sensor.; Walker Products OE |
| 2001 | Chrysler | Voyager | 2.4L | L4 | GAS | Upstream | Front oxygen sensor compatible with various vehicle models.; Walker Products OE |
| 2001 | Dodge | Caravan | 2.4L | L4 | GAS | Upstream | Bank 1 Sensor 1 needs an upstream oxygen sensor.; Walker Products OE |
| 2001 | Dodge | Caravan | 2.4L | L4 | GAS | Upstream | Front oxygen sensor compatible with various vehicle models.; Walker Products OE |
* Always verify fitment with your vehicle's VIN if unsure. Submodel & trim restrictions may apply.
This part directly replaces or is cross-referenced with the following part numbers:
Cross-reference numbers are provided for identification purposes only. Always confirm fitment before ordering.