OE Quality
60-Day Returns

Walker 250-24628 Oxygen Sensor
Overview of Walker Products OE Oxygen Sensor 250-24628
The Walker Products OE Oxygen Sensor 250-24628 is designed for precise emission control in select Ford, Mazda, and Suzuki vehicles. This heated oxygen sensor ensures accurate air-fuel mixture readings to support optimal engine performance and emissions compliance.
- Heated oxygen sensor with 4-wire design for reliable operation
- Specific fit for Ford 626, Mazda MPV, MX-6, Probe, and Suzuki Forenza models
- 12.52-inch wiring harness length with 20-gauge wire for durability
- Radiused polygon male connector for secure electrical connection
- Threaded mounting type with 18.0 mm thread diameter for proper installation
- Overall length of 16.06 inches to accommodate vehicle-specific fitment
Walker Products OE Brand Line Details
The Walker Products OE line focuses on delivering original equipment quality emission control components. This oxygen sensor is engineered to meet or exceed OEM specifications, providing a direct replacement that maintains factory performance standards. The 250-24628 part benefits from Walker's expertise in sensor technology, ensuring compatibility and durability for the specified vehicle applications.
Technical Description and Attributes
This oxygen sensor features a heated sensor type with a 4-wire configuration, allowing for faster sensor warm-up and improved accuracy in measuring exhaust oxygen levels. The wiring harness length of 12.52 inches and 20-gauge wire gauge measurement provide robust electrical connectivity. The radiused polygon male connector ensures a secure fit with the vehicle's wiring harness, reducing the risk of disconnection or signal loss. The sensor mounts via a threaded design with an 18.0 mm thread diameter, matching the original equipment mounting points. With an overall length of 16.06 inches, this sensor is tailored for specific fitment requirements.
Compatible Vehicles and Applications
- Ford 626
- Mazda MPV, MX-6, Probe
- Suzuki Forenza
This oxygen sensor is intended for use in emission control systems to monitor and regulate the air-fuel mixture, helping to reduce harmful exhaust emissions and maintain engine efficiency.
Common Issues Addressed by Oxygen Sensor 250-24628
- Check engine light triggered by faulty oxygen sensor readings
- Poor fuel economy due to incorrect air-fuel mixture
- Increased emissions and failed emissions tests
- Engine performance problems such as rough idling or hesitation
- Damage to catalytic converter from improper sensor function
Installation Notes and Tips
Ensure the vehicle is cool before beginning installation to avoid burns. Disconnect the battery to prevent electrical shorts. Remove the old oxygen sensor carefully to avoid damaging the exhaust manifold or wiring harness. Use anti-seize compound on the threaded portion if recommended by the vehicle manufacturer. Connect the radiused polygon male connector securely to the vehicle wiring harness. Verify proper sensor orientation and torque specifications during installation.
Quality Assurance and Warranty
Walker Products OE oxygen sensors are manufactured to meet strict quality standards and OEM specifications. While specific warranty details may vary, Walker typically offers coverage against defects in materials and workmanship. Refer to the product documentation or manufacturer for exact warranty terms related to part number 250-24628.
| Brand | Walker |
|---|---|
| Part Number | 250-24628 |
| Position | Walker Products OE, Upstream |
| Connector Gender | Male |
| Connector Shape | Radiused Polygon |
| Mounting Type | Threaded |
| Overall Length | 16.06 |
| Sensor Type | Heated |
| Thread Diameter | 18.0 |
| Universal Or Specific Fit | Specific |
| Wire Gauge Measurement | 20 |
| Wire Quantity | 4 |
| Wiring Harness Length | 12.52 |
This part fits 30 vehicles. Search below:
| Year | Make | Model | Liters | Cylinders | Fuel Type | Position | Notes |
|---|---|---|---|---|---|---|---|
| 2008 | Suzuki | Forenza | 2.0L | L4 | GAS | Upstream | Bank 1 Sensor 1 needs an upstream oxygen sensor.; Walker Products OE |
| 2008 | Suzuki | Forenza | 2.0L | L4 | GAS | Upstream | Front oxygen sensor compatible with various vehicle models.; Walker Products OE |
| 2007 | Suzuki | Forenza | 2.0L | L4 | GAS | Upstream | Bank 1 Sensor 1 needs an upstream oxygen sensor.; Walker Products OE |
| 2007 | Suzuki | Forenza | 2.0L | L4 | GAS | Upstream | Front oxygen sensor compatible with various vehicle models.; Walker Products OE |
| 2006 | Mazda | MPV | 3.0L | V6 | GAS | Upstream Front | Front upstream oxygen sensor needed for proper functionality near exhaust manifold.; Walker Products OE |
| 2006 | Suzuki | Forenza | 2.0L | L4 | GAS | Upstream | Bank 1 Sensor 1 needs an upstream oxygen sensor.; Walker Products OE |
| 2006 | Suzuki | Forenza | 2.0L | L4 | GAS | Upstream | Front oxygen sensor compatible with various vehicle models.; Walker Products OE |
| 2005 | Mazda | MPV | 3.0L | V6 | GAS | Upstream Front | Front upstream oxygen sensor needed for proper functionality near exhaust manifold.; Walker Products OE |
| 2004 | Mazda | MPV | 3.0L | V6 | GAS | Upstream Front | Front upstream oxygen sensor needed for proper functionality near exhaust manifold.; Walker Products OE |
| 2003 | Mazda | MPV | 3.0L | V6 | GAS | Upstream Front | Front upstream oxygen sensor needed for proper functionality near exhaust manifold.; Walker Products OE |
| 2002 | Mazda | MPV | 3.0L | V6 | GAS | Upstream Front | Front upstream oxygen sensor needed for proper functionality near exhaust manifold.; Walker Products OE |
| 2001 | Mazda | MPV | 2.5L | V6 | GAS | Upstream Rear | Calif-ESV Upstream Rear Oxygen Sensor; Walker Products OE |
| 2001 | Mazda | MPV | 2.5L | V6 | GAS | Upstream Rear | Non California engine, no California engine, upstream position, rear location; Walker Products OE |
| 2001 | Mazda | MPV | 2.5L | V6 | GAS | Upstream Rear | Non Calif-ESV Upstream Rear Oxygen Sensor; Walker Products OE |
| 2000 | Mazda | 626 | 2.5L | V6 | GAS | Center | Non Calif-ESV No Calif-ESV Center Oxygen Sensor; Walker Products OE |
| 2000 | Mazda | 626 | 2.5L | V6 | GAS | Center | Non Calif-ESV; Center; Walker Products OE |
| 2000 | Mazda | MPV | 2.5L | V6 | GAS | Upstream Rear | Non California engine, no California engine, upstream position, rear location; Walker Products OE |
| 2000 | Mazda | MPV | 2.5L | V6 | GAS | Upstream Rear | Calif-ESV Upstream Rear Oxygen Sensor; Walker Products OE |
| 2000 | Mazda | MPV | 2.5L | V6 | GAS | Upstream Rear | Non Calif-ESV Upstream Rear Oxygen Sensor; Walker Products OE |
| 1999 | Mazda | 626 | 2.5L | V6 | GAS | Center | Center position oxygen sensor; Walker Products OE |
| 1998 | Mazda | 626 | 2.5L | V6 | GAS | Center | Center position oxygen sensor; Walker Products OE |
| 1997 | Ford | Probe | 2.0L | L4 | GAS | Upstream | Bank 1 Sensor 1 needs an upstream oxygen sensor.; Walker Products OE |
| 1997 | Ford | Probe | 2.0L | L4 | GAS | Upstream | Front oxygen sensor compatible with various vehicle models.; Walker Products OE |
| 1997 | Mazda | 626 | 2.5L | V6 | GAS | Center | Center position oxygen sensor; Walker Products OE |
| 1997 | Mazda | MX-6 | 2.5L | V6 | GAS | Center | Center position oxygen sensor; Walker Products OE |
| 1996 | Ford | Probe | 2.5L | V6 | GAS | Downstream Front | Downstream front oxygen sensor required.; Walker Products OE |
| 1996 | Ford | Probe | 2.0L | L4 | GAS | Upstream | Bank 1 Sensor 1 needs an upstream oxygen sensor.; Walker Products OE |
| 1996 | Ford | Probe | 2.0L | L4 | GAS | Upstream | Front oxygen sensor compatible with various vehicle models.; Walker Products OE |
| 1996 | Mazda | 626 | 2.5L | V6 | GAS | Downstream Front | Downstream front oxygen sensor required.; Walker Products OE |
| 1996 | Mazda | MX-6 | 2.5L | V6 | GAS | Downstream Front | Downstream front oxygen sensor required.; Walker Products OE |
* Always verify fitment with your vehicle's VIN if unsure. Submodel & trim restrictions may apply.
This part directly replaces or is cross-referenced with the following part numbers:
Cross-reference numbers are provided for identification purposes only. Always confirm fitment before ordering.