/live/media/O2/O2_25024629_Fro.jpg)
Will it fit your vehicle?
Confirm before you buy. Free return shipping if it doesn't fit.
Walker 250-24629 Oxygen Sensor
| Brand | Walker 250-24629 |
|---|---|
| Position | Downstream, Upstream, Downstream Front, and Upstream Front |
| Wiring Harness Length | 10.35 |
| Wire Gauge Measurement | 20 |
| Sensor Type | Heated |
| Universal Or Specific Fit | Specific |
| Wire Quantity | 4 |
| Connector Shape | Radiused polygon |
| Connector Gender | Female |
| Thread Diameter | 18.0 |
| Overall Length | 13.9 |
| Mounting Type | Threaded |
| Product line | Walker Products OE |
| Fits | Ford and Mazda · 27 vehicles |
OE replacement. Engineered as an original-equipment-style sensor for reliable ECU feedback.
Heated sensor. Helps the system reach operating temperature faster for consistent performance.
Threaded mount. Installs with a threaded design for a secure, straightforward fit.
Will it fit your vehicle?
Free return shipping if it doesn't fit.
Walker OE Oxygen Sensor for Mazda and Ford
Walker Products OE 250-24629 is a heated oxygen sensor built for specific vehicle applications and ECU feedback requirements. It is engineered as an OE-style replacement for select Mazda Millenia, Mazda 626, Mazda MX-6, and Ford Probe models with the correct fitment position and connector configuration.
For drivers diagnosing a check engine light, poor fuel economy, or elevated exhaust emissions, this oxygen sensor helps restore accurate exhaust monitoring. The Walker Products OE line focuses on application-specific replacement parts for vehicles that need the correct sensor location and signal response.
Key Features
- Heated oxygen sensor for faster operating temperature
- Specific fit design for the listed Mazda and Ford applications
- 4-wire configuration with female connector
- Threaded mounting type with 18.0 mm thread diameter
- Radiused polygon connector shape for proper vehicle-side connection
- 10.35 wiring harness length and 13.9 overall length
- Walker Products OE part number 250-24629
Product Details
Walker Products OE is the brand line for application-specific engine management and oxygen/air-fuel sensors developed as OE replacement parts. Part number 250-24629 is built for the exact sensor position required by the vehicle ECU, helping maintain proper feedback from the exhaust stream. This matters on Mazda 626 upstream Bank 1 Sensor 1 applications, Mazda Millenia upstream front and downstream front applications, Mazda MX-6 upstream applications, and Ford Probe downstream applications.
Fits 1995-1996 Mazda Millenia, downstream front; fits 1996-1997 Mazda 626, upstream; fits 1996-1997 Mazda MX-6, upstream; fits 1996-1997 Ford Probe, downstream; fits 1997-2000 Mazda Millenia, upstream front; fits 1998-2000 Mazda 626, upstream; fits 2001-2002 Mazda Millenia, downstream front. This part cross-references no listed alternate part numbers in the provided data.
Common Issues This Sensor May Address
- Check engine light related to oxygen sensor performance
- Poor fuel economy from incorrect exhaust feedback
- Rough engine operation caused by inaccurate air-fuel readings
- Higher exhaust emissions from a failing sensor
- Stored ECU fault codes tied to the affected sensor circuit
Installation Notes and Tips
Verify the sensor position before installation, since this part is application-specific and position-sensitive. Inspect the wiring harness and connector for heat damage, abrasion, or corrosion before replacing the sensor. Confirm the vehicle’s emissions calibration, especially on 1998-2000 Mazda 626 applications where California-emissions vehicles are excluded from the listed fitment.
Quality Assurance
Walker Products has produced engine management and fuel system components since 1946 and operates as an ISO 9001/TS 16949 certified company. The OE product line is developed for specific vehicle applications and diagnostic feedback requirements.
| Year | Make | Model | Transmission | Liters | Cylinders | Fuel Type | Position | Notes |
|---|---|---|---|---|---|---|---|---|
| 2002 | Mazda | Millenia | — | 2.5L | V6 | GAS | Downstream Front | Downstream front oxygen sensor required.; Walker Products OE |
| 2001 | Mazda | Millenia | — | 2.5L | V6 | GAS | Downstream Front | Downstream front oxygen sensor required.; Walker Products OE |
| 2000 | Mazda | 626 | — | 2.0L | L4 | GAS | Upstream | Non California emissions certified; Bank 1 Sensor 1; Upstream position; Not suitable for California emissionscertified vehicles; Walker Products OE |
| 2000 | Mazda | 626 | — | 2.0L | L4 | GAS | Upstream | For vehicles without California and Federal Emissions - Upstream Bank 1 Sensor 1.; Walker Products OE |
| 2000 | Mazda | 626 | — | 2.0L | L4 | GAS | Upstream | Upstream oxygen sensor for bank 1 sensor 1 incompatible with California-ESV vehicles.; Walker Products OE |
| 2000 | Mazda | Millenia | — | 2.5L | V6 | GAS | Upstream Front | Front upstream oxygen sensor needed for proper functionality near exhaust manifold.; Walker Products OE |
| 1999 | Mazda | 626 | — | 2.0L | L4 | GAS | Upstream | Non California emissions certified; Bank 1 Sensor 1; Upstream position; Not suitable for California emissionscertified vehicles; Walker Products OE |
| 1999 | Mazda | 626 | — | 2.0L | L4 | GAS | Upstream | For vehicles without California and Federal Emissions - Upstream Bank 1 Sensor 1.; Walker Products OE |
| 1999 | Mazda | 626 | — | 2.0L | L4 | GAS | Upstream | Upstream oxygen sensor for bank 1 sensor 1 incompatible with California-ESV vehicles.; Walker Products OE |
| 1999 | Mazda | Millenia | — | 2.5L | V6 | GAS | Upstream Front | Front upstream oxygen sensor needed for proper functionality near exhaust manifold.; Walker Products OE |
| 1998 | Mazda | 626 | — | 2.0L | L4 | GAS | Upstream | Non California emissions certified; Bank 1 Sensor 1; Upstream position; Not suitable for California emissionscertified vehicles; Walker Products OE |
| 1998 | Mazda | 626 | — | 2.0L | L4 | GAS | Upstream | For vehicles without California and Federal Emissions - Upstream Bank 1 Sensor 1.; Walker Products OE |
| 1998 | Mazda | 626 | — | 2.0L | L4 | GAS | Upstream | Upstream oxygen sensor for bank 1 sensor 1 incompatible with California-ESV vehicles.; Walker Products OE |
| 1998 | Mazda | Millenia | — | 2.5L | V6 | GAS | Upstream Front | Front upstream oxygen sensor needed for proper functionality near exhaust manifold.; Walker Products OE |
| 1997 | Ford | Probe | — | 2.0L | L4 | GAS | Downstream | Fits downstream bank 1 sensor 2 on specific vehicle models.; Walker Products OE |
| 1997 | Mazda | 626 | Automatic | 2.0L | L4 | GAS | Upstream | Bank 1 Sensor 1 needs an upstream oxygen sensor.; Walker Products OE |
| 1997 | Mazda | 626 | Automatic | 2.0L | L4 | GAS | Upstream | Front oxygen sensor compatible with various vehicle models.; Walker Products OE |
| 1997 | Mazda | Millenia | — | 2.5L | V6 | GAS | Upstream Front | Front upstream oxygen sensor needed for proper functionality near exhaust manifold.; Walker Products OE |
| 1997 | Mazda | MX-6 | Automatic | 2.0L | L4 | GAS | Upstream | Bank 1 Sensor 1 needs an upstream oxygen sensor.; Walker Products OE |
| 1997 | Mazda | MX-6 | Automatic | 2.0L | L4 | GAS | Upstream | Front oxygen sensor compatible with various vehicle models.; Walker Products OE |
| 1996 | Ford | Probe | — | 2.0L | L4 | GAS | Downstream | Fits downstream bank 1 sensor 2 on specific vehicle models.; Walker Products OE |
| 1996 | Mazda | 626 | Automatic | 2.0L | L4 | GAS | Upstream | Bank 1 Sensor 1 needs an upstream oxygen sensor.; Walker Products OE |
| 1996 | Mazda | 626 | Automatic | 2.0L | L4 | GAS | Upstream | Front oxygen sensor compatible with various vehicle models.; Walker Products OE |
| 1996 | Mazda | Millenia | — | 2.5L | V6 | GAS | Downstream Front | Downstream front oxygen sensor required.; Walker Products OE |
| 1996 | Mazda | MX-6 | Automatic | 2.0L | L4 | GAS | Upstream | Bank 1 Sensor 1 needs an upstream oxygen sensor.; Walker Products OE |
| 1996 | Mazda | MX-6 | Automatic | 2.0L | L4 | GAS | Upstream | Front oxygen sensor compatible with various vehicle models.; Walker Products OE |
| 1995 | Mazda | Millenia | — | 2.5L | V6 | GAS | Downstream Front | Downstream front oxygen sensor required.; Walker Products OE |
| No rows match your filter. | ||||||||