OE Quality
60-Day Returns

Walker 250-24992 Oxygen Sensor - Downstream Left or Downstream Right
Overview of Walker 250-24992 Oxygen Sensor for Ford F-150
The Walker 250-24992 oxygen sensor is designed specifically for Ford F-150 models, providing precise emission control and engine performance monitoring. This heated oxygen sensor ensures accurate readings for optimal fuel efficiency and reduced emissions.
- Heated oxygen sensor with 4 wires for reliable operation
- Specific fit for Ford F-150 vehicles
- 13.31-inch wiring harness length for flexible installation
- Threaded mounting type with 18.0 mm thread diameter
- Radiused polygon female connector for secure connection
- 20 gauge wire measurement for durability and signal integrity
- Overall length of 16.85 inches to accommodate engine bay layout
Detailed Product Description
This Walker Products OE oxygen sensor (part number 250-24992) is engineered to meet the exact specifications of Ford F-150 trucks. Featuring a heated sensor type, it quickly reaches operating temperature to provide accurate oxygen level readings. The sensor includes a 13.31-inch wiring harness and four wires, allowing for precise signal transmission and compatibility with the vehicle’s engine control unit. The radiused polygon female connector ensures a secure and proper fit, while the threaded mounting type with an 18.0 mm diameter allows for straightforward installation in the exhaust system.
Walker Products OE is a product line focused on delivering original equipment quality parts that match or exceed factory standards. This oxygen sensor is part of that line, ensuring reliable performance and durability for emission control systems in Ford F-150 trucks.
Common Applications and Issues Addressed
- Helps maintain proper air-fuel mixture for efficient combustion
- Reduces harmful emissions by providing accurate oxygen level data
- Prevents engine performance issues related to faulty oxygen sensors
- Resolves check engine light triggers caused by sensor failure
- Improves fuel economy by enabling precise engine management
Installation Notes and Tips
- Ensure vehicle compatibility with Ford F-150 before installation
- Use appropriate tools for threaded mounting to avoid damage
- Verify connector type matches the vehicle’s wiring harness (radiused polygon female)
- Handle wiring harness carefully to prevent wire damage
- Follow manufacturer torque specifications for sensor installation
Quality Assurance and Warranty
The Walker 250-24992 oxygen sensor is manufactured to meet stringent quality standards under the Walker Products OE line. It undergoes rigorous testing to ensure durability and reliable performance in emission control applications. While specific warranty details are not provided here, Walker typically offers coverage consistent with OEM replacement parts, supporting long-term use in Ford F-150 vehicles.
| Brand | Walker |
|---|---|
| Part Number | 250-24992 |
| Position | Walker Products OE, Downstream Left |
| Connector Gender | Female |
| Connector Shape | Radiused Polygon |
| Mounting Type | Threaded |
| Overall Length | 16.85 |
| Sensor Type | Heated |
| Thread Diameter | 18.0 |
| Universal Or Specific Fit | Specific |
| Wire Gauge Measurement | 20 |
| Wire Quantity | 4 |
| Wiring Harness Length | 13.31 |
This part fits 16 vehicles. Search below:
| Year | Make | Model | Liters | Cylinders | Fuel Type | Position | Notes |
|---|---|---|---|---|---|---|---|
| 2014 | Ford | F-150 | 6.2L | V8 | GAS | Downstream Right | Install downstream oxygen sensor on the right side.; Walker Products OE |
| 2014 | Ford | F-150 | 6.2L | V8 | GAS | Downstream Left | Downstream left oxygen sensor required.; Walker Products OE |
| 2014 | Ford | F-150 | 5.0L | V8 | FLEX | Downstream Right | Install downstream oxygen sensor on the right side.; Walker Products OE |
| 2014 | Ford | F-150 | 5.0L | V8 | FLEX | Downstream Left | Downstream left oxygen sensor required.; Walker Products OE |
| 2013 | Ford | F-150 | 6.2L | V8 | GAS | Downstream Right | Install downstream oxygen sensor on the right side.; Walker Products OE |
| 2013 | Ford | F-150 | 6.2L | V8 | GAS | Downstream Left | Downstream left oxygen sensor required.; Walker Products OE |
| 2013 | Ford | F-150 | 5.0L | V8 | FLEX | Downstream Right | Install downstream oxygen sensor on the right side.; Walker Products OE |
| 2013 | Ford | F-150 | 5.0L | V8 | FLEX | Downstream Left | Downstream left oxygen sensor required.; Walker Products OE |
| 2012 | Ford | F-150 | 6.2L | V8 | GAS | Downstream Right | Install downstream oxygen sensor on the right side.; Walker Products OE |
| 2012 | Ford | F-150 | 6.2L | V8 | GAS | Downstream Left | Downstream left oxygen sensor required.; Walker Products OE |
| 2012 | Ford | F-150 | 5.0L | V8 | FLEX | Downstream Right | Install downstream oxygen sensor on the right side.; Walker Products OE |
| 2012 | Ford | F-150 | 5.0L | V8 | FLEX | Downstream Left | Downstream left oxygen sensor required.; Walker Products OE |
| 2011 | Ford | F-150 | 6.2L | V8 | GAS | Downstream Right | Install downstream oxygen sensor on the right side.; Walker Products OE |
| 2011 | Ford | F-150 | 6.2L | V8 | GAS | Downstream Left | Downstream left oxygen sensor required.; Walker Products OE |
| 2011 | Ford | F-150 | 5.0L | V8 | FLEX | Downstream Right | Install downstream oxygen sensor on the right side.; Walker Products OE |
| 2011 | Ford | F-150 | 5.0L | V8 | FLEX | Downstream Left | Downstream left oxygen sensor required.; Walker Products OE |
* Always verify fitment with your vehicle's VIN if unsure. Submodel & trim restrictions may apply.
This part directly replaces or is cross-referenced with the following part numbers:
Cross-reference numbers are provided for identification purposes only. Always confirm fitment before ordering.